ANTSPACE HD5 V1 Dry cooling tower

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide

HD5 is the largest and most operationally different container in this library. It introduces a dual A/B liquid-cooling architecture, a 308-server density target, and a much heavier power and weight profile than HK3 or HW5.

Manual revision V1.0.2
Container size 12196 x 2438 x 2896 mm
Server capacity Up to 308 S21/S19 Hydro servers
Standard / max power 1512 kW / 1665 kW
ANTSPACE HD5 dry cooling tower guide

The HD5 manual marks another major break in the Bitmain container line. The document describes two A/B liquid-cooling systems that can run independently or together while sharing a main control cabinet.

That architecture changes deployment, operations, and maintenance, so crews need to read the manual through planning and service work, not installation alone.

PDF Download

Download the Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide PDF

Download the PDF, then use the sections below to review specs, setup steps, power and cooling requirements, maintenance notes, troubleshooting details, and revision history for Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide.

V1.0.2 January 2025 100 pages

Comparison

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide: Version Differences

  • HD5 introduces two A/B liquid-cooling thermal systems that can run separately or together while sharing a main control cabinet.
  • The container grows to support up to 308 S21/S19 Hydro servers, well above the 210-unit HK3 and HW5 families.
  • Power scales up sharply: 1512 kW standard, 1665 kW maximum, and 1200A x4 main switching capacity in the distribution layer.
  • HD5 uses a dry-cooling-tower system with a 1500 kW tower package and DN100 external interfaces instead of HW5's dry-wet branch.

Quick Specs

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide Specs and Requirements

Container dimensions 12196 x 2438 x 2896 mm
High-calculation server capacity Up to 308 S21 Hyd. and S19 Hyd. series servers
Standard / max power 1512 kW / 1665 kW
Main switching capacity 1200A x 4
Dry cooling tower capacity 1500 kW
Interfaces / flow DN100 PN16 external interface, rated flow 67.2-73.9 m3/h depending on pump frequency

Installation

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide Setup Highlights

  • Level the container, install the dry-cooling towers, lift them into place, and lay out the intermediate connection pipework exactly as the HD5 guide shows.
  • Treat the A and B cooling systems as a commissioning concern from day one because the manual describes them as separate loops that can run independently.
  • Use the distribution-work chapter carefully because HD5 has a heavier electrical and switching profile than HK3 or HW5.
  • Complete the onsite installation summary before power-up so the A/B loop architecture is fully validated.

Utilities

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide Power and Cooling Requirements

  • HD5 uses forced-air dry cooling towers only in this manual, not dry-wet or PHE variants.
  • The container supports 1512 kW standard power and 1665 kW maximum power, with 1200A x4 main switching capacity.
  • The dry cooling tower package is rated at 1500 kW and <=80 kW operating power.
  • Rated flow is shown as 67.2-73.9 m3/h depending on pump frequency, which is different from the >=85 m3/h target used in the HK3/HW5 manuals.

Operations

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide Operation Notes

  • The manual covers system use, pressurization, rehydration, electrical wiring, power-up/power-down, and touch-screen operation from the perspective of the A/B system split.
  • Operators can energize loop A, loop B, or both depending on the site's configuration and available server population.
  • Field builds using dual-loop HD5 architecture should stay on this manual instead of the single-loop HK3 or HW5 guides.
  • The larger server count and heavier power profile make disciplined startup sequencing even more important on HD5.

Maintenance

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide Maintenance Notes

  • The HD5 guide includes dedicated container troubleshooting, dry cooling tower troubleshooting, and maintenance/upkeep sections.
  • Because the system can run as A, B, or both, maintenance planning needs to account for loop isolation and staged service windows.
  • HD5 is not the place to improvise with HK3/HW5 service habits; the guide's own architecture differences justify a separate maintenance playbook.
  • Use the HD5 guide to compare expansion plans against smaller Bitmain container families.

Troubleshooting

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide Troubleshooting Notes

  • Use the HD5 manual first when the site has an A/B loop issue, because that architecture does not exist in HK3 or HW5.
  • The dry cooling tower troubleshooting section is separate from the container troubleshooting section, which helps isolate whether the problem is in the loop or the tower package.
  • HD5's power scale means distribution and loop-state checks should happen before server-level assumptions are made.

Files

Bitmain ANTSPACE HD5 V1 Dry Cooling Tower Guide PDF Download and Revision History

Product Manual

HD5 V1 Dry Cooling Tower Product Manual

Covers the HD5 dual-loop A/B architecture and the larger 308-server container footprint.

Version
V1.0.2
Date
January 2025
Pages
100

Revision Archive

  • HD5 V1 product manual V1.0.2 · January 2025

    Current HD5 dry cooling tower manual with dual-loop A/B architecture and the larger 308-server configuration.